• Contact Us:+86 769 8203 3052
    Mon-Fri | 09:00 - 18:00  UTC+8

BMS/PCM/PCB - LiFePO4 BMS/PCM/PCB

BMS D706 for 25.6V 8S LiFePO4 Battery Packs (10A Charge, 35A Discharge)

1. Protection Circuit Board for 25.6V 8S LiFePO4 battery pack;
2. PCM applies for 8 cells LiFePO4 battery pack with E-Switch integrated, E-Switch can totally turn off the output;
3. To prevent the battery packs from over charge, over discharge, over current, over temperature ,short circuit;
4. Compatible with LiFePO4 cells; 
5. How balancing function works? After battery pack is fully charged. PCM will detect each cell's voltage and trim higher voltage down until other cells reach the same voltage level. Therefore, it helps cells have longer service life.
6. PCM comes with all the voltage detection wires and connectors.
 
We keep materials in stock only, we need around 3-7 days for samples productions.

Sale Price:$
Quantity Amount
1-50$43.59
51-100 $43.09
101-200 $42.59
200+ $41.59
Weight:58g Model:
Total cost:

Quantity: (stock:

  • Product detail
  • DownLoad

Item
Content Criterion
Model
HCX-D706LF08S35A-03/BQ 77905 8S-35A working current
Voltage
Charging voltage 28.8V
Current
Maximal continuous charging current 10A
Maximal continuous discharging current 35A
Current consumption ≤50uA
Overcharge Protection
Over charge detection voltage 3.9V±0.025V
Over charge detection delay time 0.5S-1.5S
Over charge release voltage 3.7V±0.05V
Over Discharge Protection
Over discharge detection voltage 2.00±0.05V
Over discharge detection delay time 0.5S-1.5S
Over discharge release voltage 2.40±0.1V
Over Current Protection
(1st Protection)
Over current detection voltage 0.085±0.01V
Over current detection current 70A±10A
Detection delay time 640-825mS
Release condition Cut load, automatically recover
Over Current Protection
(2nd Protection)
Over current detection voltage 0.12±0.02V
Over current detection current 140A±20A
Detection delay time 320-405mS
Release condition Cut load, automatically recover
Short Circuit Protection
Short circuit detection current external resistance ≤ 0.1Ω
Detection delay time 220-610uS
Detection condition Cut load, automatically recover
Balance
Balance voltage for single cell /
Balance current for single cell /
Resistance
Inner resistance ≤20mΩ
Temperature
Operating temperature range -20 ~ +85°C
Storage temperature range -20 ~ +125°C
Size(L*W*T)